VCS VIP 1000 Manuel d'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
64 en | Appendix VIP XD
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
No audio transmission to
remote station.
Hardware fault. Check that all connected audio
units are operating correctly.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
Incorrect configuration. Check the audio parameters on
the Audio configuration page.
The audio voice connection is
already in use by another
receiver.
Wait until the connection is free
and then call the sender again.
The unit does not report
an alarm.
Alarm source is not selected. Select possible alarm sources on
the Alarm Inputs configuration
page.
No alarm response specified. Specify the desired alarm
response on the Alarm
Connections configuration page,
change the IP address if
necessary.
Control of cameras or
other units is not
possible.
The cable connection between
the serial interface and the
connected unit is not correct.
Check all cable connections and
ensure all plugs are properly
fitted.
The interface parameters do not
match those of the other unit
connected.
Make sure that the settings of all
units involved are compatible.
The unit is not
operational after a
firmware upload.
Power failure during
programming by firmware file.
Have the unit checked by
Customer Service and replace if
necessary.
Incorrect firmware file. Enter the IP address of the unit
followed by /main.htm in your
Web browser and repeat the
upload.
Placeholders with a red
cross are displayed
instead of the ActiveX
components.
Sun JVM is not installed on the
computer or is not enabled.
Install Sun JVM from the
product CD.
Web browser contains
empty fields.
Active proxy server in network. Create a rule in the local
computer's proxy settings to
exclude local IP addresses.
If a sender is connected
to the receiver, the first
connection remains.
Auto-connect configured. Deactivate auto-connect.
Malfunction Possible causes Recommended solution
Vue de la page 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 79 80

Commentaires sur ces manuels

Pas de commentaire