Configuring the Sender Chapter 6
52 VIP 10
Click Select area to configure the sensor fields. A new window will open.
If necessary, click Clear all first to clear the current selection (fields marked
red).
Left-click the fields to be activated. Activated fields are marked red.
Click Select all to select the entire video frame for monitoring.
Right-click any fields you wish to deactivate. "Inactive" fields are marked white.
Click Set to save the configuration.
Click the close button (X) in the window title bar to close the window without
saving the changes.
Local sensitivity
The basic sensitivity of the video sensor can be adjusted for the environmental
conditions to which the camera is subject.
The sensor reacts to variations in the brightness of the video image. The darker
the observation area, the higher the value that must be selected.
Adjust the sensitivity by dragging the scroll thumb to the desired setting.
Average (n frames)
You can define the number of frames for which a movement is monitored before
generating an alarm. This helps prevent false alarms from events such as a bird
flying across the surveillance area.
Select the value by dragging the scroll thumb to the desired position.
Object min size (n*n blocks)
You can specify the number of sensor fields that a moving object must cover to
generate an alarm. This is to prevent objects that are too small from triggering an
alarm.
A minimum value of 2 (2 × 2 sensor fields) is recommended.
Select the value by dragging the scroll thumb to the desired position.